W22XM is one of WEG flameproof TEFC three phase motors lines for group I - mines and is available for shaft height 315 up to 500.
W22XM line is available for Low, Medium and High voltage with the following powers:
W22XM - Low voltage (¡Â 1100 V): IE2 Efficiency level / according IEC60034-30
Powers (kW)
RPM
132 up to 1120
3000 / 3600
132 up to 1400
1500 / 1800
90 up to 1120
1000 / 1200
75 up to 900
750 / 900
W22XM - Medium voltage (1100 V < U ¡Â 6600 V):
Powers (kW)
RPM
90 up to 1200
3000 / 3600
90 up to 1500
1500 / 1800
90 up to 1250
1000 / 1200
90 up to 1000
750 / 900
W22XM - High voltage (6600 V < U ¡Â 11000 V):
Powers (kW)
RPM
355 up to 710
3000 / 3600
355 up to 900
1500 / 1800
280 up to 630
1000 / 1200
200 up to 500
750 / 900
In relation to the different available optionals, W22XM motors are designated as follows:
W22XM – Standard Ex d I Mb motor
W22XME – Ex d e I Mb motor
W22XMS – Ex d I Mb motor with sleeve bearings
W22XMES – Ex d e I Mb motor with sleeve bearings
Particular specifications related to Hazardous Areas
This motor series has the CE marking in compliance with European Directive 94/9/EC (ATEX) and is also certified in accordance with IECEx Scheme. The applicable standards are:
EN 60079-0: Explosive Atmospheres - Part 0: Equipment – General requirements
EN 60079-1: Explosive Atmospheres - Part 1: Equipment protection by flameproof enclosure ¡®d¡¯
EN 60079-7: Explosive Atmospheres - Part 7: Equipment protection by increases safety ¡®e¡¯
W22XM motors are classified as equipment Group I (Mines), suitable to use on category M2.
As standard, W22XB motors are supplied for Zone 1 application - IIB Group of Gases and Temperature class T4 (under request T5 is available).
As standard execution, W22XM motors are fitted with flameproof terminal boxes, with specification code Ex d, I. Under request and as an alternative execution, these motors can be fitted with an Increased Safety terminal box. In this case the description code is Ex d e, I. These flameproof motors are certified according to the above standards, by the EU accredited Notified Body INERIS in France.
Main standard construction
Mechanical protection: IP66
Insulation: Class F
Temperature rise: 80 K
Frames: are in cast iron
Terminal boxes: are in cast iron
Endshields: are in cast iron
Fans: Cast iron / Welded steel
Fan cover:Welded steel, capable to withstand impact of 20 Joule (IK10).
Finish: polyurethane paint scheme 212P, standard color RAL 2003.
Main construction optionals
Insulation: Class H
Temperature rise: 105 K
Frames:Welded construction
Terminal boxes:Welded construction
Endshields:Welded construction
Several optional features are available for W22XM line. Please requrest the full scope to WEGeuro.
Voltage and frequency
As standard, Low Voltage motors are wound to operate on ¥Ä 400 V - 50 Hz. As an option ¥Ä 460 V - 60 Hz is available.
As standard Medium Voltage motors are wound to operate on Y6000 V - 50Hz. As an option Y 3000 V - 50 Hz or Y4160 V - 60 Hz are available.
As standard High Voltage motors are wound to operate on Y10000 V - 50Hz. Other supply voltages and frequencies can be supplied under request.
W22XM line is also available for VSD application.
Motors are manufactured within the tolerances given by IEC 60034-1.
Ambient temperature and altitude
W22XM standard motors are manufactured for an ambient temperature -20¨¬C up to +40¨¬C and altitude up to 1000m. As an option motors can be executed for an ambient temperature up to +60¨¬C and altitude up to 5000m.
Basic design
Cooling method: IC 411 in accordance with standard IEC 60034-6 - motors cooled by an external fan.
Direction of rotation: Bidirectional. 2 poles motors for frame size 450 and above are unidirectional (customer must define sense of rotation with the order).
Electrical connection: LV: The terminal boxes are provided with 6 terminals, to connect the motors to the mains supply, allowing the star/delta starging. For currents higher than 1090A 12 terminals are used. MV/HV: The terminal boxes are provided with 3 terminals, to connect the motors to the mains supply.
Terminal boxes: The main terminal box is located at top of motor frame and can be rotated by 180¨¬ to suit cable entry from left or right hand side. As standard, the supply cable entries are on the left hand side when viewed from shaft end. Note: customer must refer cable entry direction with order.
Protections/Auxiliaries: As standard the W22XM Low Voltage motors are fitted with 3 PTC thermistors, (triple, 2 wire), connected in the main terminal box. As standard the W22XM Medium and High Voltage motors are equipped with 2xPT-100/phase (3 wires), 1xPT-100/bearing (3 wires) and space heaters, connected in an auxiliary terminal box. Under request the motors can be fitted with more than one auxiliary terminal box.
Earth connection: All motors are equipped with an earth connection inside of terminal box. A second external earth connection is also provided on motor frame, on foot or on flange, depending on mounting form.
Terminal box entries and cable glands: As standard, the motors are not supplied with cable glands and the number of entry holes and respective dimensions are described on outline dimensions tables. However, considering that the cable entry makes part of the protection enclosure it is recommended that the motors are supplied from factory fitted with cable glands. For this it is necessary to specify with the order the complete cabling details (number of cables, specification, section and diameters), so that the motors can be supplied from factory fitted with suitable glands.
Bearings: As general rule, W22XM motors are equipped with deep groove ball bearings in both sides for horizontal mounting form. Some arrangements foresee the use of roller bearing in NDE or 3 bearings mounting. W22XM vertical motors are equipped with deep groove ball bearings in both sides up to frame size 355 and with an angular contact bearing in DE side for frame sizes 400 and above. For horizontal motors is available roller bearing execution in drive end side defined according to the radial loads involved on the application. For vertical motors is available for all motors angular contact bearing execution in drive end side defined according to the axial loads involved on the application. As optional motors can be supplied with sleeve bearings execution.
Lubrication: The motors are equipped with grease relief valves and relubrication nipples.
Balancing: The motors are dynamically balanced with half-key to meet the vibration limits of standard IEC 60034-14, Grade A. Grade B can be provided under request.